NI LabVIEW LINX by NI - Toolkit for LabVIEW
System Design Suite 2.0 or 2.1 LabVIEW NXG 2.1 USRP-2900/2901 √ √ √ USRP-2920/2921/2922 √ √ √ USRP-2930/2932 √ √ √ USRP-2940/2942/2943/2944 √ √ √‡ USRP-2950/2952/2953/2954 √ √ √‡ USRP-2945/2955 √† USRP-2974 √** † The USRP-2945/2955 is not supported in LabVIEW 2015 SP1. ‡ Support for the USRP RIO API and modifying the LV FPGA bitfile is only supported in LabVIEW Communications System Design Suite. ** NI-USRP 18.1 does not include support for the USRP-2974 in LabVIEW Communications System Design Suite 2.1. Note NI-USRP is not supported in LabVIEW NXG 2.0 or earlier. Accessing the API NI-USRP and USRP RIO palette VIs and nodes are available in the following palette locations. API LabVIEW LabVIEW Communications System Design Suite 2.0 LabVIEW NXG or LabVIEW Communications System Design Suite 2.1 NI-USRP Functions»Instrument I/O»Instrument Drivers»NI-USRP Hardware Interfaces»NI-USRP Hardware Interfaces>>Wireless Design and Test>>NI-USRP USRP RIO Functions»Instrument I/O»Instrument Drivers»USRP RIO Hardware Interfaces»USRP RIO Hardware Interfaces>>Wireless Design and Test>>USRP RIO Finding Examples, Lessons, and Sample Projects NI-USRP examples, lessons, and sample projects are available in the following locations. Content Type Description LabVIEW LabVIEW Communications System Design Suite 2.0 LabVIEW NXG or LabVIEW Communications System Design Suite 2.1 Examples NI-USRP includes several example applications that serve as interactive tools, programming models, and building blocks in your own applications. NI-USRP includes examples for getting started and other software-defined radio (SDR) functionality. Note You can access additional examples from the Code Sharing Community at ni.com/usrp. From the Start menu at Start»All Programs»National Instruments»NI-USRP»Examples. From the LabVIEW Functions palette at Instrument I/O»Instrument Drivers»NI-USRP»Examples. From the Learning tab, select Examples»Hardware Input and Output»NI USRP Host. From the Learning tab, select Examples»Hardware Input and Output»NI USRP RIO. From the Learning tab, select Examples»Hardware Input and Output»NI-USRP. From the Learning tab, select Examples»Hardware Input and Output»USRP RIO. Lessons NI-USRP includes lessons that guide you through the process of identifying and demodulating an FM signal with your device. N/A From the Learning tab, select Getting Started»Demodulating FM Signals with the NI... and choose a task to accomplish. From the Learning tab, select Getting Started»Demodulating FM Signals with the NI... and choose a task to accomplish. Sample Projects USRP RIO includes several sample projects that serve as starting points to build a USRP RIO streaming application. From the Create Project dialog, select Sample Projects in the left pane and navigate to the NI-USRP Simple Streaming project. From the Projects tab, choose the applicable sample project for your device and setup. From the Projects tab, select USRP RIO and choose the applicable sample project for your device and setup. Accessing the Documentation Documentation for NI-USRP is located at Start»All Programs»National Instruments»NI-USRP»Documentation and online at ni.com/manuals. The documentation set is composed of the following documents. Document Format My LabVIEW, LabWindows/CVI, Measurement Studio, or TestStand Built Installer Fail on Windows XP/Vista and Server 2003?. Product Security and Critical Updates Visit ni.com/security to view and subscribe to receive security notifications about NI products. Visit ni.com/critical-updates for information about critical updates from NI. Activation Notice To activate the Advanced Signal Processing Toolkit, use the serial number you received with the software kit. You can find your serial number on the product packing slip or on the shipping label. The serial number activates the LabVIEW Advanced Signal Processing Toolkit, the LabVIEW System Identification Assistant, and the LabVIEW Digital Filter Design Toolkit. Your purchase of the Advanced Signal Processing Toolkit enables you to use the LabWindows™/CVI™ Advanced Signal Processing Toolkit. To request the installation media for the LabWindows/CVI Advanced Signal Processing Toolkit, contact NI. Known Issues You can access the software and documentation known issues list online. Refer to the NI website for an up-to-date list of known issues in LabVIEW 2016 Advanced Signal Processing Toolkit. Accessing the Help Refer to the LabVIEW Help, accessible by selecting Help»LabVIEW Help from LabVIEW, for information about the Advanced Signal Processing Toolkit. Finding Examples Select Help»Find Examples from LabVIEW to launch the NI Example Finder. The following table lists the examples for the Advanced Signal Processing Toolkit and the directory which contains the examples. Examples Directory Time Frequency Analysis labview\examples\Time Frequency Analysis Time Series Analysis labview\examples\Time Series Analysis Wavelet Analysis labview\examples\Wavelet Analysis System Identification labview\examples\System Identification You can modify an example VI to fit an application, or you can copy and paste from one or more examples into a VI that you create. Automating the Installation of NI Products You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes. However, starting with the August 2012 releases (products using NI Installers version 3.1 or later), you may need to perform additional steps before or during a silent installation of NI software. If the NI product you are installing uses Microsoft .NET 4.0, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.0 separately before you install NI software. For more information about automating the installation of NI products, refer to the following KnowledgeBase articles: For more information about silent installations ofNI LabVIEW Scripting by NI - Toolkit for LabVIEW Download
There are three locations from which LabVIEW loads Quick Drop Keyboard Shortcut plugins. Install your plugin to whichever location makes the most sense based on the criteria below.Option 1: LVAddons folderLocation: [Program Files]\NI\LVAddons\[plugin name]\[plugin version]\resource\dialog\QuickDrop\pluginsSupported LabVIEW versions: LabVIEW 2025 Q1 and laterYour plugin must install [Program Files]\NI\LVAddons\[plugin name]\[plugin version]\lvaddoninfo.json that contains the following contents: { "AddonName": "[plugin name]”, "ApiVersion": "v[plugin version]", "MinimumSupportedLVVersion": "[version in xx.y format, e.g. 25.1]" }Plugins installed in LVAddons are accessible in any LabVIEW version equal to or newer than the MinimumSupportedLVVersion. These plugins are available to any user logged in to the computer.The plugin VI(s) must have the 'Separate compiled code from source file' option CHECKED.Option 2: LabVIEW 20xx folderLocation: [LabVIEW 20xx]\resource\dialog\QuickDrop\pluginsSupported LabVIEW versions: LabVIEW 2009 and laterPlugins installed in [LabVIEW 20xx] are only accessible in that version of LabVIEW.These plugins are available to any user logged in to the computer.Save the plugin VI(s) in this LabVIEW version to improve load time performance of the plugin.Option 3: LabVIEW Data folderLocation: [LabVIEW Data]\Quick Drop PluginsSupported LabVIEW versions: LabVIEW 2010 and laterYou can use Tools > Options > Paths > Default Data Directory to find out where the LabVIEW Data folder is on your system.Plugins installed here are available in any LabVIEW installed on the system that is equal to or newer than the version used to save the plugin VI(s).These plugins are available only to the user account that contains the LabVIEW Data folder.If you are using an installer or NI Package Manager (NIPM) to distribute your plugin with LabVIEW 2025 Q1 or later, NI recommends using Option 1. If you are using VIPM to distribute your plugin, NI recommends using Option 2. If you are manually installing a plugin and want to share it across different instances of LabVIEW, NI recommends using Option 3.. LabVIEW- LabVIEW- LabVIEW, NI System Configuration- LabVIEW, NI System Configuration- LabVIEW- LabVIEW- LabVIEW- LabVIEW- LabVIEW- LabVIEW- LabVIEW- LabVIEW- LabVIEW- LabVIEW- -NI LabVIEW Base Licenses (Perpetual and Subscription licenses) LabVIEW Core 1 - NI LabVIEW Full Licenses. LabVIEW Core 1-NI LabVIEW Professional Licenses. LabVIEWScripting Languages and NI LabVIEW - NI
Certified LabVIEW Plug and Play (project-style) Instrument Driver Driver Specifications Manufacturer(s): Rigol Technologies Interface(s): USB, Ethernet Instrument Type(s): Signal Generator Driver Version: 1.0.1 Original Release Date: 26-SEP-2012 Update Release Date 07-JAN-2013 Models Tested: DG4162 Other Supported Models: See Below NI Certified? Yes NI Supported? Yes Driver Ratings: 2 Ratings | 3 out of 5 Download Driver and Related SoftwareUse the chart below to download the right driver for your ADE. To download the required software, visit Drivers and Updates. Application Development Environment Minimum Software Required LabVIEW 8.2.1 Upgrade NI-VISA 5.4Login to Download LabVIEW 2015 Upgrade NI-VISA 5.4Login to Download LabVIEW 2016 Upgrade NI-VISA 5.4Login to Download LabVIEW 2017 Upgrade NI-VISA 5.4Login to Download LabVIEW 2018 Upgrade NI-VISA 5.4Login to Download LabVIEW 2021 Upgrade NI-VISA 5.4Login to Download Models Supported by this Driver Models Tested? Description DG4062 Arbitrary Waveform Generator DG4102 Arbitrary Waveform Generator DG4162 Yes Arbitrary Waveform Generator Interface Type (optional) What Interface Are You Using?In order to help us prioritize future development, please select the primary interface you intend to use with this driver: NI Product Bundle, use the installation media that shipped with your purchase to install this product. (macOS, Linux) You can install the MathScript Module using the LabVIEW 2019 media for macOS/Linux. Refer to the LabVIEW Media Readme for macOS/Linux for instructions on how to install the MathScript Module. Product Security and Critical Updates Visit ni.com/security to view and subscribe to receive security notifications about NI products. Visit ni.com/critical-updates for information about critical updates from NI. Known Issues You can access the software and documentation known issues list online. Visit ni.com/info and enter the Info Code lvms2019ki for an up-to-date list of known issues in the LabVIEW 2019 MathScript Module. Accessing the Help Refer to the LabVIEW Help, accessible from Help»LabVIEW Help from LabVIEW, for information about the MathScript Module. Finding Examples Select Help»Find Examples from LabVIEW to launch the NI Example Finder. LabVIEW examples for the MathScript Module are located in the labview\examples\MathScript directory. You can modify an example VI to fit an application, or you can copy and paste from one or more examples into a VI that you create. Automating the Installation of NI Products You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes. If the NI product you are installing uses Microsoft .NET 4.6.2, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.6.2 separately before you install NI software. For more information about automating the installation of NI products, refer to the following KnowledgeBase articles: For more information about silent installations of individual NI products, refer to Customize and Automate Installation of a Single Installer. For more information about silent installations of NI products in a suite, such as NI Software Platform Bundle, refer to Customize and Automate Installation of a Suited Installer. To determine what version of NI Installers your product contains, refer to Determine Type and Version of My National Instruments Installer. Using NI Software with Microsoft Windowslabview 6i to labview 8 - NI Community
March 2018 This file contains important information about LabVIEW 2018 for Linux, including system requirements, installation instructions, known issues, and a partial list of bugs fixed for LabVIEW 2018. Refer to the NI website for the latest information about LabVIEW. Refer to the labview/readme directory for readme files about LabVIEW add-ons, such as modules and toolkits. System Requirements Installation Instructions Product Security and Critical Updates Supported Modules and Toolkits Supported Drivers Known Issues Bug Fixes Accessing the Help Additions to the LabVIEW Help Legal Information System Requirements LabVIEW 2018 for Linux has the following requirements: Linux Run-Time Engine Development Environment Processor Pentium 4 G1 (or equivalent) or later Pentium 4 G1 (or equivalent) or later RAM 256 MB 1 GB Screen Resolution 1024 x 768 pixels 1024 x 768 pixels Operating System Linux kernel 2.6x or 3.x GNU C Library (glibc) Version 2.11 or later for the Intel x86_64 architecture openSUSE LEAP 42.2 openSUSE LEAP 42.3 Red Hat Enterprise Linux Desktop + Workstation 6.x Red Hat Enterprise Linux Desktop + Workstation 7.x CentOS 7 Disk Space 98 MB 1.1 GB for the complete installation Color Palette N/A LabVIEW and the LabVIEW Help contain 16-bit color graphics. LabVIEW requires a minimum color palette setting of 16-bit color. Temporary Files Directory N/A LabVIEW uses a directory for storing temporary files. NI recommends that you have several megabytes of disk space available for this temporary directory. Adobe Reader N/A You must have Adobe Reader installed to search PDF versions of all LabVIEW manuals. Note LabVIEW 2018 for Linux is available only in 64-bit. LabVIEW and LabVIEW Run-Time Engine require 64-bit processors which support SSE2 instructions. Installation Instructions Complete the following steps to install and activate LabVIEW for Linux. Are you installing LabVIEW for the first time? Insert and mount the LabVIEW installation media. As the root user in the mounted directory, enter sh ./INSTALL to install LabVIEW in the /usr/local directory. To install LabVIEW modules and toolkits, refer to the readme of each product for installation instructions. The VI Analyzer Toolkits installs with the LabVIEW Professional Development System for Linux. You can install NI device drivers from ni.com/linuxdrivers. Are you upgrading from a previous version of LabVIEW? Refer to the LabVIEW Upgrade Notes for information about protecting existing VIs and projects before installing a new version of LabVIEW, as well as upgrade and compatibility issues and a complete list of new features in LabVIEW 2018. Note If you purchased this product with an NI Software Suite or NI Product Bundle, use the installation media that shipped with your purchase to install this product. Product Security and Critical Updates Visit ni.com/security for security information about NI products. Visit ni.com/critical-updates for information about critical updatesLabView 5.1 - LabView 6i - NI Community
Upgrade LabVIEW FilesLaunch the version of LabVIEW you wish to upgrade your code.From the File menu, select Open… and navigate to the location of the file you wish to upgrade.Select OK to open your files. If errors exist in the new version, use debugging tools to rectify them. From the File menu, select Save As to save this newer version of your LabVIEW code. Note: If you use Save instead of Save As, this will save over the original version of the code. Code from various versions can exist alongside each other. The best practice is to keep the original version of your code while in the process of upgrading. [Suggested] Mass Compile your code to maintain links between VIs and subVIs. This will also check for any corrupted VIs. A single file or an entire directory can be selected for mass compilation and the items will be opened in the new version, saved, and then closed. Note on Upgrading from Legacy Versions of LabVIEWTo open a VI created before LabVIEW 6 in LabVIEW 8.5 or later, you must first convert the VI to a LabVIEW version between 6 and 8.2. In this situation, NI recommends upgrading to LabVIEW 8.2.1 as an intermediate version because it is the version of LabVIEW closest to the current.Customers with active software subscription licenses or service agreements can access older versions of LabVIEW by contacting NI support.Once you have upgraded to a version after 6.0, you can continue with the steps above.Note on Upgrading from Legacy Versions of NI-DAQIf your VIs uses legacy NI-DAQ functions, these will need to be replaced with the new NI-DAQmx functions. For a more detailed guide about the differences between the two data acquisition functions and recommendations for the migration visit: Transition from Traditional NI-DAQ (Legacy) to NI-DAQmx in LabVIEW .. LabVIEW- LabVIEW- LabVIEW, NI System Configuration- LabVIEW, NI System Configuration- LabVIEW- LabVIEW- LabVIEW- LabVIEW- LabVIEW- LabVIEW- LabVIEW- LabVIEW- LabVIEW- LabVIEW- -NI LabVIEW Base Licenses (Perpetual and Subscription licenses) LabVIEW Core 1 - NI LabVIEW Full Licenses. LabVIEW Core 1-NI LabVIEW Professional Licenses. LabVIEWNI LabVIEW LINX Toolkit for LabVIEW - Download
LabVIEW 2017 y posterioresEn 2017, NI trasladó la distribución de software macOS a descargas en línea. Si está buscando instalar versiones más nuevas de LabVIEW para macOS , puede encontrar las siguientes instrucciones sobre Cómo descargar e instalar el software de NI .Tenga en cuenta que deberá iniciar sesión en su cuenta asociada con el SSP activo para cualquier descarga de LabVIEW para macOS.Para todas las versiones anterioresPara todas las versiones anteriores de LabVIEW para macOS, debe obtener una copia física del software para instalarlo. NI distribuye LabVIEW para macOS y está vinculado a su número de serie. Si actualmente tiene un contrato SSP, puede solicitar acceso a medios físicos (en inglés) sin costo.Otras versionesVersiones académicas :Para todas las versiones académicas de LabVIEW para macOS, debe obtener una copia física del software para instalarlo. Comuníquese con el administrador de su sitio, quien puede solicitar acceso a medios físicos (en inglés) si es necesario.Versión de evaluación:Si actualmente no tiene una copia comprada de LabVIEW para macOS, puede descargar una versión de evaluación de LabVIEW para macOS (en inglés) de NI. La versión de evaluación estará activa durante el período de prueba.Cuando decida pasar de la versión de evaluación a la versión con licencia de LabVIEW en macOS, tendrá que instalar una versión con licencia siguiendo las instrucciones en Descargar Software de NI .Nota: Solo la última versión publicada de LabVIEW está disponible para descargar para uso de evaluación.Comments
System Design Suite 2.0 or 2.1 LabVIEW NXG 2.1 USRP-2900/2901 √ √ √ USRP-2920/2921/2922 √ √ √ USRP-2930/2932 √ √ √ USRP-2940/2942/2943/2944 √ √ √‡ USRP-2950/2952/2953/2954 √ √ √‡ USRP-2945/2955 √† USRP-2974 √** † The USRP-2945/2955 is not supported in LabVIEW 2015 SP1. ‡ Support for the USRP RIO API and modifying the LV FPGA bitfile is only supported in LabVIEW Communications System Design Suite. ** NI-USRP 18.1 does not include support for the USRP-2974 in LabVIEW Communications System Design Suite 2.1. Note NI-USRP is not supported in LabVIEW NXG 2.0 or earlier. Accessing the API NI-USRP and USRP RIO palette VIs and nodes are available in the following palette locations. API LabVIEW LabVIEW Communications System Design Suite 2.0 LabVIEW NXG or LabVIEW Communications System Design Suite 2.1 NI-USRP Functions»Instrument I/O»Instrument Drivers»NI-USRP Hardware Interfaces»NI-USRP Hardware Interfaces>>Wireless Design and Test>>NI-USRP USRP RIO Functions»Instrument I/O»Instrument Drivers»USRP RIO Hardware Interfaces»USRP RIO Hardware Interfaces>>Wireless Design and Test>>USRP RIO Finding Examples, Lessons, and Sample Projects NI-USRP examples, lessons, and sample projects are available in the following locations. Content Type Description LabVIEW LabVIEW Communications System Design Suite 2.0 LabVIEW NXG or LabVIEW Communications System Design Suite 2.1 Examples NI-USRP includes several example applications that serve as interactive tools, programming models, and building blocks in your own applications. NI-USRP includes examples for getting started and other software-defined radio (SDR) functionality. Note You can access additional examples from the Code Sharing Community at ni.com/usrp. From the Start menu at Start»All Programs»National Instruments»NI-USRP»Examples. From the LabVIEW Functions palette at Instrument I/O»Instrument Drivers»NI-USRP»Examples. From the Learning tab, select Examples»Hardware Input and Output»NI USRP Host. From the Learning tab, select Examples»Hardware Input and Output»NI USRP RIO. From the Learning tab, select Examples»Hardware Input and Output»NI-USRP. From the Learning tab, select Examples»Hardware Input and Output»USRP RIO. Lessons NI-USRP includes lessons that guide you through the process of identifying and demodulating an FM signal with your device. N/A From the Learning tab, select Getting Started»Demodulating FM Signals with the NI... and choose a task to accomplish. From the Learning tab, select Getting Started»Demodulating FM Signals with the NI... and choose a task to accomplish. Sample Projects USRP RIO includes several sample projects that serve as starting points to build a USRP RIO streaming application. From the Create Project dialog, select Sample Projects in the left pane and navigate to the NI-USRP Simple Streaming project. From the Projects tab, choose the applicable sample project for your device and setup. From the Projects tab, select USRP RIO and choose the applicable sample project for your device and setup. Accessing the Documentation Documentation for NI-USRP is located at Start»All Programs»National Instruments»NI-USRP»Documentation and online at ni.com/manuals. The documentation set is composed of the following documents. Document Format
2025-04-06My LabVIEW, LabWindows/CVI, Measurement Studio, or TestStand Built Installer Fail on Windows XP/Vista and Server 2003?. Product Security and Critical Updates Visit ni.com/security to view and subscribe to receive security notifications about NI products. Visit ni.com/critical-updates for information about critical updates from NI. Activation Notice To activate the Advanced Signal Processing Toolkit, use the serial number you received with the software kit. You can find your serial number on the product packing slip or on the shipping label. The serial number activates the LabVIEW Advanced Signal Processing Toolkit, the LabVIEW System Identification Assistant, and the LabVIEW Digital Filter Design Toolkit. Your purchase of the Advanced Signal Processing Toolkit enables you to use the LabWindows™/CVI™ Advanced Signal Processing Toolkit. To request the installation media for the LabWindows/CVI Advanced Signal Processing Toolkit, contact NI. Known Issues You can access the software and documentation known issues list online. Refer to the NI website for an up-to-date list of known issues in LabVIEW 2016 Advanced Signal Processing Toolkit. Accessing the Help Refer to the LabVIEW Help, accessible by selecting Help»LabVIEW Help from LabVIEW, for information about the Advanced Signal Processing Toolkit. Finding Examples Select Help»Find Examples from LabVIEW to launch the NI Example Finder. The following table lists the examples for the Advanced Signal Processing Toolkit and the directory which contains the examples. Examples Directory Time Frequency Analysis labview\examples\Time Frequency Analysis Time Series Analysis labview\examples\Time Series Analysis Wavelet Analysis labview\examples\Wavelet Analysis System Identification labview\examples\System Identification You can modify an example VI to fit an application, or you can copy and paste from one or more examples into a VI that you create. Automating the Installation of NI Products You can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes. However, starting with the August 2012 releases (products using NI Installers version 3.1 or later), you may need to perform additional steps before or during a silent installation of NI software. If the NI product you are installing uses Microsoft .NET 4.0, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.0 separately before you install NI software. For more information about automating the installation of NI products, refer to the following KnowledgeBase articles: For more information about silent installations of
2025-04-20There are three locations from which LabVIEW loads Quick Drop Keyboard Shortcut plugins. Install your plugin to whichever location makes the most sense based on the criteria below.Option 1: LVAddons folderLocation: [Program Files]\NI\LVAddons\[plugin name]\[plugin version]\resource\dialog\QuickDrop\pluginsSupported LabVIEW versions: LabVIEW 2025 Q1 and laterYour plugin must install [Program Files]\NI\LVAddons\[plugin name]\[plugin version]\lvaddoninfo.json that contains the following contents: { "AddonName": "[plugin name]”, "ApiVersion": "v[plugin version]", "MinimumSupportedLVVersion": "[version in xx.y format, e.g. 25.1]" }Plugins installed in LVAddons are accessible in any LabVIEW version equal to or newer than the MinimumSupportedLVVersion. These plugins are available to any user logged in to the computer.The plugin VI(s) must have the 'Separate compiled code from source file' option CHECKED.Option 2: LabVIEW 20xx folderLocation: [LabVIEW 20xx]\resource\dialog\QuickDrop\pluginsSupported LabVIEW versions: LabVIEW 2009 and laterPlugins installed in [LabVIEW 20xx] are only accessible in that version of LabVIEW.These plugins are available to any user logged in to the computer.Save the plugin VI(s) in this LabVIEW version to improve load time performance of the plugin.Option 3: LabVIEW Data folderLocation: [LabVIEW Data]\Quick Drop PluginsSupported LabVIEW versions: LabVIEW 2010 and laterYou can use Tools > Options > Paths > Default Data Directory to find out where the LabVIEW Data folder is on your system.Plugins installed here are available in any LabVIEW installed on the system that is equal to or newer than the version used to save the plugin VI(s).These plugins are available only to the user account that contains the LabVIEW Data folder.If you are using an installer or NI Package Manager (NIPM) to distribute your plugin with LabVIEW 2025 Q1 or later, NI recommends using Option 1. If you are using VIPM to distribute your plugin, NI recommends using Option 2. If you are manually installing a plugin and want to share it across different instances of LabVIEW, NI recommends using Option 3.
2025-04-04Certified LabVIEW Plug and Play (project-style) Instrument Driver Driver Specifications Manufacturer(s): Rigol Technologies Interface(s): USB, Ethernet Instrument Type(s): Signal Generator Driver Version: 1.0.1 Original Release Date: 26-SEP-2012 Update Release Date 07-JAN-2013 Models Tested: DG4162 Other Supported Models: See Below NI Certified? Yes NI Supported? Yes Driver Ratings: 2 Ratings | 3 out of 5 Download Driver and Related SoftwareUse the chart below to download the right driver for your ADE. To download the required software, visit Drivers and Updates. Application Development Environment Minimum Software Required LabVIEW 8.2.1 Upgrade NI-VISA 5.4Login to Download LabVIEW 2015 Upgrade NI-VISA 5.4Login to Download LabVIEW 2016 Upgrade NI-VISA 5.4Login to Download LabVIEW 2017 Upgrade NI-VISA 5.4Login to Download LabVIEW 2018 Upgrade NI-VISA 5.4Login to Download LabVIEW 2021 Upgrade NI-VISA 5.4Login to Download Models Supported by this Driver Models Tested? Description DG4062 Arbitrary Waveform Generator DG4102 Arbitrary Waveform Generator DG4162 Yes Arbitrary Waveform Generator Interface Type (optional) What Interface Are You Using?In order to help us prioritize future development, please select the primary interface you intend to use with this driver: